Why can't the GOAT find or be connected to the docking station correctly?

Updated on 2024/04/15
1) Confirm if the docking station is faulty: Whether the docking station indicator is off.
*In case of a docking station fault, ECOVACS Customer Care should be contacted.
(2) Check whether the station is installed correctly according to the installation instruction manual. GOAT returns to the station in a counterclockwise direction along the lawn edge. There are certain rules for the placement direction of the station. Please refer to the instruction manual for details.
(3) Check whether the docking station is not powered on or is powered off halfway.
(4) Check whether the docking station has been moved to another position.
(5) Check whether the route for returning to charge has been blocked or there are obstacles within 1 meters of the docking station.
(6) Check whether the white reflective film inside the docking station is covered or damaged.
(7) Check if there is copper rust on the charging contacts on the docking station or GOAT. If there is, wipe it off.
(8) Check if there are reflective objects near the docking station similar to the white reflective film inside the docking station (for example: deployed umbrellas, highly reflective metal railings, reflective straps, shoes and laces of fluorescent material, reflective mirrors, reflective signposts, etc.) that are misleading the GOAT.
(9) Check if the AI camera at the front of GOAT is clean.
If the issue persists, please contact ECOVACS Customer Care.
Was this article helpful?